Hospitals Moving Toward Greater Use of Insulin Pens

| Nov 10, 2011

The introduction of insulin pen devices in the 1980s facilitated accurate and simple administration of insulin for people managing their diabetes on an outpatient basis. The use of insulin in hospitals, however, continues to be associated with medication errors and severe adverse events.  Published practice guidelines have helped address insulin error prevention, and the availability of diabetes technologies has presented another opportunity to promote the safe use of insulin in hospitals.

A number of institutions have considered the advantages of insulin pen devices over a vial and syringe and have made the transition for subcutaneous administration of insulin. Insulin pen devices offer a number of safety features for use in a hospital setting, including patient-specific dose formulation, convenient dose measurement, accurate dose delivery, and shielded safety needles.

Because pens are increasingly used in the outpatient setting, it is also reasonable to conclude that pen devices used at the bedside of a hospitalized patient could facilitate patient education in using the devices.  One satisfaction study showed that significantly more hospitalized patients receiving insulin via pen wanted to continue that method of insulin delivery at home.

Some of the drawbacks to switching from a vial and syringe method of insulin delivery to an insulin pen include the inability to mix different types of insulins (so multiple injections may be required), as well as the need for comprehensive staff education, new hospital policies, and surveillance of nursing personnel to detect unforeseen problems resulting from the change in duties.

The institution where I practice as a pharmacist is a 440-bed tertiary care hospital located in Salisbury, Maryland.  Upon completion of a favorable cost-analysis and approval of the plan by management and related departments, the conversion from vial and syringe to insulin pens was initiated in February 2007.  Collaborative education efforts focused on training a core group of nurse managers, who would then train nurses in their respective stations.

Additional education was provided by clinical pharmacists and a staff pharmacist who was also a certified diabetes educator.  Personnel were required to complete competency-based insulin pen training and demonstrations before the devices could be used to administer subcutaneous insulin.

The pharmacy department substituted vials for the corresponding Lantus® Opticlik pen, and the prefilled pens for Humulin® N, Humulin® 70/30, Humalog®, and the various Humalog mix formulations.  The pen needle available at the time was the BD Autoshield® (12.7 mm in length), which fit on all pen devices. It also had a safety feature of locking after injection to prevent reuse and reduce risk of needlestick injuries.  The emergency department continued to use vials of insulin for expected single patient doses and for large-volume intravenous products.

In addition to medical and nursing staff education, pharmacy staff were trained on proper labeling of the products. This included placement of a patient-specific label near the top of the pen (not on the cap) adjacent to the dosing window without covering the manufacturer product information, and placement of appropriate auxiliary labels (expiration date, "do not refrigerate" warning) and tamperproof tape over the cap.

The system-wide change to insulin pen devices presented a number of challenges that were managed with an effective, multidisciplinary surveillance and communication system. 

What We Learned During This Experience

Injection technique is critical for preventing accidental needlestick injuries.  The original BD Autoshield® utilized for each injection was a shielded, fairly long needle that seemed relatively bulky to those unfamiliar with its use.  Nurses who held the insulin pen at an angle while injecting, rather than straight into the skin at 90 degrees, were found to be at a higher risk of an accidental needlestick.  It was also discovered that the skin area to be pinched up for the injection should be fairly wide: approximately one inch of skin between the fingers after the pinch is completed.  Hospital administrators acted quickly to address these issues with additional education and changed to a shorter-length, shielded needle as soon as it became available.

In addition, many nurses wanted visual confirmation that the insulin dose was given, similar to watching insulin being pushed by the barrel along the length of a transparent syringe. However, they couldn't see that happen through the shielded needle and pen.  After an injection had been completed, nurses noted that a drop of insulin was left on the skin, leading some to believe that the full dose was not given.  Feedback was provided to nurses that, in actuality, the residual on the skin was most likely from the tip of the needle after the pen was primed.

An insulin pen should not be used for multiple patients.  This question arose early in the program, and education was provided during the initial training.  One goal of the program was to provide patient-specific insulin therapy.  However, a literature review revealed case reports at several institutions of one patient's insulin pen being used on another patient because nurses believed that by changing the pen needle between patients, the insulin would not be contaminated.  At least two studies have reported that biological contamination was found in up to half of insulin pens studied.

Insulin should not be withdrawn from the pen cartridge as if it were a vial.  This situation occurred in the beginning of our program after a nurse reported that she had trouble getting the insulin pen to work. Consequently, she used a syringe to withdraw the insulin from the pen cartridge and gave the dose to the patient with the syringe.  The pharmacist replaced the insulin pen and explained that pulling insulin out of the pen cartridge can introduce an air bubble into the pen device and cause the device to dial up an inaccurate dose for the next injection.  The practice may also contaminate the insulin remaining in the pen device.

In a number of instances, nurses called the pharmacy asking if it is appropriate to allow patients to take an insulin pen with them upon discharge for home use.  On these occasions, it was important to clarify hospital policy that it is against Joint Commission (JCAHO) regulations for patients to take home medications that were purchased through hospital contract prices. 

Once the system issues involved in the transition were addressed, the experience reported by nurses appeared to be similar to published reports in the literature. One satisfaction survey of 54 registered nurses in a community hospital where insulin pens were implemented on two surgical floors resulted in 70 to 80 percent of nurses agreeing that the pens were convenient and simple to use.  However, 39 percent of nurses responded negatively with regard to feeling more confident in giving the correct dose and feeling more comfortable using the pen device than using a syringe and vial.

Over time, changes were made to optimize the safety and accuracy of the insulin pen program, including updating the required education and periodic proficiency testing of nursing staff, replacing the Lantus Opticlik® with the disposable Lantus SoloSTAR®, and implementing color-coded pens to better distinguish different types of insulin.

As technology in diabetes management evolves, it is important for an institution to fully evaluate how a new safety initiative will impact patient care.  With adequate preparation, effective communication, comprehensive education, and continuous monitoring, hospitals can greatly improve health outcomes and reduce the risk for medication errors.

Sources:

(1)  American Society of Health-System Pharmacists. Professional practice recommendations for safe use of insulin in hospitals. http://www.ashp.org/s_ashp/docs/files/Safe_Use_of_Insulin.pdf  (accessed 2011 Oct 7).

(2)  Greenwood B, Szumita PM, Pendergrass M. Conversion to insulin devices in the inpatient setting. Am J Health Syst Pharm. 2008;65:698-699.

(3)  Davis EM, Christensen CM, Nystrom KK, Foral PA, Destache C. Am J Health-Syst Pharm. 2008;65(14):1347-1357.

(4)  BD Product Information...  http://www.bd.com/injection/products/autoshield/

(5)  Institute for Safe Medication Practices. Hazard Alert: Reuse of insulin pen for multiple patients risks transmission of bloodborne disease.  Medication Safety Alert! Acute Care Ed. 2009;14(3):1-2. www.wbamc.amedd.army.mil/documents/PressReleases/02062009.html

(6) Institute for Safe Medication Practices. Considering insulin pens for routine hospital use? Consider this.  Medication Safety Alert! Acute Care Ed. 2008;13(9):1-3.  http://www.ismp.org/newsletters/acutecare/articles/20080508.asp

(7)  Davis EM, Bebee A, Crawford L, Destache C.  Nurse satisfaction using insulin pens in hospitalized patients.  The Diabetes Educator. 2009(Sep/Oct);35(5).

 

Click Here To View Or Post Comments

Categories: Color-Coded Pens, Diabetes, Diabetes, Dose Delivery, Dose Measurement, Insulin, Insulin Delivery, Insulin Dose, Insulin Pens, JCAHO, Lantus, Needlestick, Patient-Specific Insulin Therapy, Shielded Needle, Vial and Syringe


Take the Diabetes Health Pump Survey
See What's Inside
Read this FREE issue now
For healthcare professionals only
  • What's on the Horizon with Diabetes Research and Therapy
See the entire table of contents here!

You can view the current or previous issues of Diabetes Health online, in their entirety, anytime you want.
Click Here To View

See if you qualify for our free healthcare professional magazines. Click here to start your application for Pre-Diabetes Health, Diabetes Health Pharmacist and Diabetes Health Professional.

Learn More About the Professional Subscription

Free Diabetes Health e-Newsletter

Latest
Popular
Top Rated
Print | Email | Share | Comments (9)

You May Also Be Interested In...


Comments

Posted by Anonymous on 10 November 2011

My father was hospitalized for something unrelated to his type 1 diabetes and it was amazing to me how inept the nursing staff was when it came to checking his blood sugar and administering insulin. Thankfully he was able to self administer the second day because it might have otherwise been trajic. I would really like to know just what are they teaching nurses about type 1 diabetes in nursing school?

Posted by Anonymous on 10 November 2011

I was recently in the hospital. They gave me my insulin with the lantus pen that I usually use, but with a different needle- probably the one you described. What I liked about it was that I didn't have to see the needle going in to me (I've never liked that and my kids get embarrassed when I do it in public). Are these hospital needles available in regular pharmacies? If not could I buy them from the hospital?

Posted by Anonymous on 13 November 2011

In regards to the comment made about the availability of the shielded pen needles (the one preferred by the person who didn't want to see the needle during an inection):

I haven't seen them on shelves at the larger pharmacy chain stores, and they may not be found readily on shelves at your local independent/corner pharmacy, but you could ask the pharmacist whether they can be ordered for you. The shielded-needle products are made by two companies: BD (Becton-Dickinson) and NovoNordisk. If you go to their web sites you can find the specific product code (to be sure the correct item is ordered). It is important to consult with a CDE to show you how to properly attach and use the product. There are other options available to "hide" a needle during injection; the CDE can discuss that also.

For the BD Autoshield:
http://www.bd.com/us/diabetes/hcp/main.aspx?cat=63257&id=63260

For the Novofine Autocover:
novonordisk-us.com

The price might be higher for these safety needles, but be sure to get a prescription, and if your insurance rejects payment as a prescription item, you may still be able to apply payment toward a flexible spending account (if you have one) - a prescription is required for documentation in that case.

Hope this was helpful!

Posted by Anonymous on 14 November 2011

Way to go Dr. Edgeworth!! Hope to see you back at the Hospital soon for updates on Diabetes. Your colleague.

Posted by Anonymous on 15 November 2011

I find it interesting that you say they are difficult use when a mixture of insulins is needed. Does it not say on the accompanying instructions "insulin should not be mixed". This I again find interesting as there is both basal and bolus insulins available which end up being 'mixed' when they are injected at some time or other.

Posted by Anonymous on 15 November 2011

Accuracy? We tried pens and I found them to be VERY inaccurate. Dial in a dose, inject, wait, remove the needle and watch....1 to 2 full drops of insulin ooze from the needle! Equivalent to 1-unit of insulin. Is it excess? or was it supposed to be part of the dose? who knows? How is that accurate? Sure whatever a patient is initially trained on is what they will use. But don't say its accurate.

Posted by Anonymous on 16 November 2011

I started with the pens and went to the vial and syringes. Main reason was due to cost. The pens are a lot more expensive.

Posted by Anonymous on 16 November 2011

Yes, I was using an insulin pen but I switched to the syringe when I lost my insurance last year. I just got a new job, and I found out the insulin pens are covered!!! I will keep some syringes and a vial on hand in case it ever happens again - a good back up to have.

Posted by Anonymous on 22 April 2012

If I went into a hospital that was using insulin pens, I would run immediately out the door! Nurses seem to understand that you can only use 1 syringe per patient, they don't seem to get that you can only use 1 pen per patient (EVEN IF YOU CHANGE THE PEN NEEDLES!) There is backflow with pens and you can get HIV and Hep, if a nurse screws up and uses a pen on more than 1 patient. If only the FDA would publish the number of patients that have contracted HIV and Hep via insulin pens, no hospital would put insulin pens on their formulary. Do your research people, go to fda.gov and type in the search button put in "insulin pens in hospitals and you will see a couple of reports of the cross contamination." And if you have been recently been diagnosed with HIV and Hep and can't figure out how, were you recently in a hospital that uses insulin pens? You now have a lawsuit!


Add your comments about this article below. You can add comments as a registered user or anonymously. If you choose to post anonymously your comments will be sent to our moderator for approval before they appear on this page. If you choose to post as a registered user your comments will appear instantly.

When voicing your views via the comment feature, please respect the Diabetes Health community by refraining from comments that could be considered offensive to other people. Diabetes Health reserves the right to remove comments when necessary to maintain the cordial voice of the diabetes community.

For your privacy and protection, we ask that you do not include personal details such as address or telephone number in any comments posted.

Don't have your Diabetes Health Username? Register now and add your comments to all our content.

Have Your Say...


Username: Password:
Comment:
©1991-2014 Diabetes Health | Home | Privacy | Press | Advertising | Help | Contact Us | Donate | Sitemap

Diabetes Health Medical Disclaimer

The information on this site is not intended or implied to be a substitute for professional medical advice, diagnosis or treatment. All content, including text, graphics, images, and information, contained on or available through this website is for general information purposes only. Opinions expressed here are the opinions of writers, contributors, and commentators, and are not necessarily those of Diabetes Health. Never disregard professional medical advice or delay seeking medical treatment because of something you have read on or accessed through this website.